TM 888200 Rev (I), January 2014
Mechanical Specifications 21
Through the HART Protocol the detector can:
Display set-up
Reconfigure set-up
Display detector status and definition
Perform detector diagnostic
Troubleshooting
4.3 Mechanical Specifications
The Detector, Source and tilt mount are St. St. 316
Electro chemical and passivized coating.
Ex d e ib [ib Gb] IIB+H2 T4 Gb
Ex tb IIIC T135°C Db IP66
Class I Div. 1 Groups B, C, and D
Class II/III Div. 1 Groups E, F, and G
T6 -58°F (-50°C) ≤ Ta ≤ 149°F (65°C)
Approved per FM 6325
Tested by FM per EN60079-29-4
IP68 is rated for 2 meter depth for 45 minutes.
(Two options - specified at time of order)
2 X 3/4” - 14NPT conduits